Wiring the electrical system – Oasis Concepts Diesel and AC Heating System for Recreational Vehicles and Yachts User Manual

Page 39

Advertising
background image

Wiring the Electrical System

6.1 Before You Begin

The Oasis™ Heating Module and its electrical Control Board are pre-
wired and have been thoroughly tested together as a unit.

To review the wiring system for the Oasis™ Heating Module, refer
to the wiring diagram at the end of this Section 6, Figure 6-1:

System Wiring.

All electrical connections and wiring must comply with normally-

accepted 12 VDC and 120 VAC wiring practices, local regulations,
and ABYC/RVIA standards. Only a qualified electrical installer
should complete the wiring. All field wiring is to be in accordance
with CSA Standard C22.1, Canadian Electrical Code Part l or the
National Electrical Code, ANSI/NFPA 70.

Section

6

!

WARNING

6.2 12 VDC

The following apply to the 12 VDC connections for the Oasis™
Heating Module:

• There is one paired set of 12 VDC electrical connections on the

top right of the Oasis™ Heating Module. They consist of the
primary DC positive (red) and negative (black) connection and
are 14 gauge stranded copper wires.

Primary DC power should originate from a dedicated connection on

the house battery bank. A 20 amp fuse or breaker must be
included close to and inline from the battery to the positive (red)

connection on the Oasis™ Heating Module. The primary power wire
gauge must be sized to permit no more than a 3% voltage drop
from the battery to the Oasis™ Heating Module.

!

WARNING

• A properly-shielded power system is required for safe, trouble-

free operation.