Using FINS Applications

Section 6-5

• Local Network Table

• Relay Network Table

None

Example: PLC 2 and PLC 3 Routing Table Settings

• Local Network Table

• Relay Network Table

In order to relay from PLC2/3 to the final network number 1, it is necessary
to relay via node address 1 (i.e., the Controller Link Unit) on relay network
number 2.

2.

Save the routing table file (File - Save local routing table file).

3.

Select New from the Project Menu, and save with a file name. Then select
Add Device from the Project Menu. For each PLC, register a PLC with a
direct serial connection (node address: 0), and select it.

4.

With CX-Integrator, select Open from the PLC Menu.

5.

Select Routing table

−

Setup, read the saved file, and select Options

−

Transfer to PLC. Click Yes to transfer the routing tables to the connected
PLCs.

6-5-2

FinsGateway

FinsGateway Ver. 2003 must be used to communicate using FINS/TCP
between applications serving as communications drivers and CS1W-ETN21
or CJ1W-ETN21 Ethernet Units.

FinsGateway Ver. 3.

@

or lower versions can be used, however, when commu-

nicating by the FINS/UDP method only.

■

Overview of Setup Methods

1. Starting FinsGateway Settings

Select FinsGateway

−

FinsGateway Setup to start the FinsGateway Setup.

2. ETN_UNIT Driver Setup

1.

Double-click on ETN_UNIT in the settings for the network and Unit. The fol-
lowing ETN_UNIT Properties Window will be displayed.

Unit number

Local network number

0

1

1

2

Unit number

Local network number

0

2

Final network number

Relay network number

Relay node address

1

2

1