2 Instructions

2-336

CP1E CPU Unit Instructions Reference Manual(W483)

ORG

Applicable Program Areas

Operands

P: Port Specifier

C: Control Data

Operand Specifications

Instruction

Mnemonic

Variations

Function

code

Function

ORIGIN SEARCH

ORG

@ORG

889

ORG(889) performs an origin search or origin
return operation.

Symbol

ORG

Area

Step program areas

Subroutines

Interrupt tasks

Usage

OK

OK

OK

Operand

Description

Data type

Size

P

Port specifier

---

1

C

Control data

---

1

P

Port

0000 hex

Pulse output 0

0001 hex

Pulse output 1

Area

Word addresses

Indirect DM addresses

Constants

CF

Pulse bits

TR bits

CIO

WR

HR

AR

T

C

DM

@DM

*DM

P,C

---

---

---

---

---

---

---

---

---

OK

---

---

---

P: Port specifier

C: Control data

ORG(889)

P

C

0

3

4

7

8

11

12

15

C

Always 0 hex.

Always 0 hex.

Pulse output method

Mode
0 hex: Origin search
1 hex: Origin return

1 hex: Pulse + direction