Hint, Precautions, 2 instructions – Omron SYSMAC CP CP1E-N@@D@-@ User Manual

Page 407: Start code / end code settings and send data

Advertising
background image

2-371

2 Instructions

CP1E CPU Unit Instructions Reference Manual(W483)

Serial Co

mm

un
icatio

n

In

stru

ctio

ns

2

TXD

• Up to 259 bytes can be sent, including the send data (N = 256 bytes max.), the start code, and the

end code.

• Specify the size of the send data, not including the start code and end code, in N.

Start code / end code settings and send data

Hint

• When sending data to another device by TXD instruction, the device may require that the data be

sent at certain intervals. In that case, a transmission delay time can be set to adjust the transmission
intervals.

Precautions

• TXD(236) can be used only for the CPU Unit’s RS-232C port or the Serial Option Board port. In addi-

tion, the port must be set to no-protocol mode.

• Data can be sent only when the port’s Send Ready Flag is ON. (The Send Ready Flag is A392.05 for

the CPU Unit’s RS-232C port, or A392.13 for Serial Option Board port.)

• Nothing will be sent if 0 is specified for N.

ED

ᕃ ᕄ ᕅ ᕆ ᕇ ᕈ . . .

ᕃ ᕄ ᕅ ᕆ ᕇ ᕈ . . .

ST

ᕃ ᕄ ᕅ ᕆ ᕇ ᕈ . . .

ED

ᕃ ᕄ ᕅ ᕆ ᕇ ᕈ . . .

ST

LF

ᕃ ᕄ ᕅ ᕆ ᕇ ᕈ . . .

CR

ᕃ ᕄ ᕅ ᕆ ᕇ ᕈ . . .

ST

CR

LF

CR+LF End Code

Only End Code

No Start or End Code

N send bytes: 256 max.

Only Start Code

Send bytes after ST:
256 max.

Send bytes before ED:
256 max.

Start and End Code

Send bytes between
ST and ED: 256 max.

Send bytes before
CR+LF: 256 max.

Send bytes between ST
and CR+LF: 256 max.

Start and CR+LF End Code

Data sent.

S

S+1

S+2

ᕃ
ᕅ
ᕇ

ᕄ
ᕆ
ᕈ

15

7

0

8

N bytes of data is sent in the following order when sending
the most significant bytes first is specified:
ᕃ, ᕄ, ᕅ, ᕆ, ᕇ, ᕈ

CPU Unit’s built-in RS-232C port or Serial Option
Board port