Super, Dust gorilla system, Dust gorilla cfm vs. sp curve – Oneida Air Systems Super Dust Gorilla User Manual

Page 5

Advertising
background image

III. General Specifications & Fan Performance Curves

2HP Super Dust Gorilla Owner’s Manual

O.A.S. 2007

c

4

- Sleeve kit adds 7” (4” is minimum)

- 35 gal. bin is 22” dia. x 22.5” h / 55 gal. bin is 22” dia. x 35.5” h

- Several Filter Options Available- Galvanized steel construction

- The collector can be hung on the wall, from the ceiling, or free standing support using

the 10 ga. angle iron ring at the top of the cone.

(See assembly instructions)

2.0 hp

Height without

Dust Bin

Cyclone

Diameter

Inlet

Diameter

Weight without

Dust Bin

TEFC

Motors

Class F

115/230v

23/11.5 amps

1.15 Service Factor

63”

21”

Approx. Wt.

122 lbs.

w/o drum or filter

Static pressure and volume together determine

a fan’s performance. Several factors, such as

layout of ductwork and diameter of openings,

can affect a fan’s performance.

2hp

Super

Dust Gorilla System

Industrial Baldor TEFC 2hp motor

*

115/230v - 23/11.5 amps / 1.15 Service Factor
Full 16 gauge galvanized cyclone & 11 ga. fan housing
7” dia. inlet / 8” rectangular outlet
14.25” dia. x 4” wide cast aluminum fan wheel
back inclined non-sparking, non-ferrous dynamic, two-planed
balanced to ISO 6.3 specifications.
Sound 78 - 79dB @ 10’ with Built-in Silencer and Filter
95 Sq. Ft. Filter Media / Spun-Bonded

2hp

Super

Dust Gorilla CFM vs. SP Curve*

9
8

7
6

5

4
3

2

0

St

atic Pressure at Cyclone Inlet

CFM

0

200

400

600

1000

800

10

1400

1600

6.3

1200

10.65

9.4

4.3

11

8.25

3

2.3

1422 cfm @

2.3” SP w/c

w/o filter.

Vented outside.

- Without Filter
- With Filter

*Fan curves vary slightly with different filter packages.

1349 cfm @ 2.3”

SP w/c w/ filter.

FCS133900

1422 CFM @ 2.3” SP w/c w/o filter

*

* Note: Motor Starter supplied

with system is for 220v only.

Advertising