VII. Bracket Assembly

1. You must determine the direction the fan outlet will point to

proceed with this mounting assembly. The collector will seem

quieter if the outlet is aimed away from the area people tend to

work. Slots in the brackets are .406” x 1.00”

Note: Bolts included to mount bracket to collector. Hardware

NOT included to mount to wall.

2. Hold bracket against wall with top of plate at 56”. Mark where

mounting holes fall. Mount wall bracket. For wall mounting, the

bolt centers on the brackets are at 16”to accomodate most wall

stud spacing. See Fig. 1 & 2. Use a Level to ensure straightness.

3. Attach bracket to wall with lag screws, concrete anchors, or

other suitable hardware. See Fig. 2 & 3. Note: When installing

the brackets on a concrete wall, mount 2 x 4’s between wall and

brackets to stabilize and dampen vibration.

4. Position Angle Ring around top of cone over bracket. Line up

one hole in Ring with hole in each bracket at desired rotation of

outlet. If rotation you desire does not correspond to an existing

hole in Angle Ring, drill new ones. Use three 3/8” bolts (included)

with washers & lock washers to secure the fan. See Fig. 4.

5. Attach tightly with bolts. See Fig. 4.

Note: Please do not install an Oneida Dust Collection System alone. Competent

assistance is advisable. Units are heavy!

56” to top of plate.

Distance tor minimum

mounting height.

4

1

.406” x 1.00”

16”

12 Ga.

2

3

Level

24.25”

16”