Omron V400-H111 User Manual

Page 69

Advertising
background image

68

Section 4

Crea

ting Set

ting Files Using t

h

e 2DCR Conf

ig

ear

V400-H111/211

User’s Manual

Section 4
System Settings

Comparison Principle

With display conversion, comparison is performed with the data contained in the file, and the display

contents is changed to the registered text strings for characters that match.

Matching processing is performed in order starting from the beginning of the file. Once a match is

found, no further comparisons are made, i.e., matching processing is affected by the entry order.
Therefore, when comparing complicated patterns, make sure that the optimum order is used.

2.

Click [1. New Regist.].

The Conversion Registration window appears.

3.

Select the desired start position and number of bytes.

Specify the part of the read data to be compared.
Specify the data position from which comparison is to be started and the number of data bytes to be
compared.
If you want to compare all the read data, specify "1" in [Starting Position] and "All" in [Number of Bytes].

4.

Click the [Import] button.

Import the created file to the 2DCR Configear to convert the created file to a format that can be uploaded to
the Handheld 2D Code Reader

5.

Select the CSV file to be uploaded and click the [Open] button.

Advertising