background image

80

A

ppe

nd

ic

es

Spe

c

ifica

tions

a

nd
Dime

nsions

V400-H111/211

User’s Manual

Appendices

V400-H111

V400-H211

Field of vision

5 to 10 mm

15 to 30 mm

Working distance

40 mm (contact with the code when the Contactor is mounted)

Power supply voltage

5 VDC ± 10 %

Current consumption

1 A max.

Serial interface

RS-232C

Applicable code

DataMatrix ECC200 10

× 10 to 64 Ч 64, 8 Ч 18 to 16 × 48

QR Code Model 1.2 21

× 21 to 57 × 57 (Ver. 1 to 10)

Operating method

Pushbutton control using the trigger buttons

System Settings

Operation in the Setup window (on Code Reader), uploading setting data using
a Memory Card, or communication by “2DCR Configear”

Memory Card

SD card

Monitor

1.8-inch TFT liquid crystal display for displaying image and read data

Indicators

Power indicator and Memory Card access indicator

Ambient temperature

Operating: 0 to 40°C Storage: -25 to 60°C

Ambient humidity

35% to 85%(with no condensation)

Ambient environment

No corrosive gases

Vibration resistance

10 to 150 Hz ; half-amplitude: 0.35 mm (max. acceleration: 50 m

2

/s)

Shock resistance

150m

2

/s 3 times in 6 directions

Weight

Approx. 230 g

Degree of protection

IEC 60529 (IP64)

Materials

Case: ABS; Optical surface: PC; Display: PMMA