Appendix a troubleshooting, Main status indicator, Restoring the okilan 6120 i to factory defaults – Oki 6120i User Manual

Page 142

Advertising
background image

IV - 49

Section 4 - Appendix A - Troubleshooting

OKI OkiLAN 6120i User’s Guide

TCP/IP

Appendix A
Troubleshooting

Main Status Indicator

Upon power-up, the main status indicator flashes
orange. It changes to green when the OkiLAN 6120i
passes self-test. The indicator stays orange if the
OkiLAN 6120i fails self-test. If the indicator turns
solid orange due to an error, a configuration sheet will
be printed automatically. Check the error message
reported on the configuration sheet.

Restoring the OkiLAN 6120

i

to

Factory Defaults

In most cases, the best way to restore the OkiLAN
6120i to factory defaults is via telnet. However, if you
are unable to connect to the device because of a
configuration error, use the following method which
does not require a network connection.

To restore the OkiLAN 6120i to factory defaults,
complete the following steps:

1. Power down the OkiLAN 6120i.

2. While holding in the Print Configuration Sheet

Test button, power up the OkiLAN 6120i. Hold the
button until the status indicator turns solid green.

3. Power cycle the OkiLAN 6120i. It will have

restored itself to defaults.

Advertising