Operation action comments 1, Installer manual 13 – Orbit Manufacturing Rokonet ORBIT-6 RP-206 User Manual

Page 13

Advertising
background image

Installer Manual

13

Operation

Action

Comments

1

Enter the

Installer
Programming

mode

enter the factory default
Installer Code (

0-2-0-6);

followed by

#

a long beep will sound, confirming
successful entry into Installer
Programming

2

Access the

current Installer

Code
(stored in location
“08”)

press

[0], [8], [ARM]

no confirming beep will sound

3

Enter a unique
Installer Code
(for this tutorial,
we’ll use 3-0-5-7)

enter

[3], [0], [5], [7]

no confirming beep will sound

4

Store the data
you have entered

press

[#]

a long beep will sound confirming that
data has been properly stored
if a wrong number of digits entered
three (error) beeps will sound after
pressing #

press

keys

displayed

zone

LEDs

lit

value

none

1

st

digit

2, 1

3

STAY
STAY

2

nd

digit

none

0

STAY
STAY

3

rd

digit

3,1

5

STAY
STAY

4

th

digit

3,2,1

7

5

Check the data
stored in Location
“08”

the first digit of the stored

data will appear

observe the Zone LEDs

press

[STAY] [STAY] to

advance to the next digit

once all four digits have

been displayed, attempts to
view an additional digit will
result in three (error) beeps

if desired, press

[STAY]

and

[ARM] to move

backwards

6

Go to another

location of your
choice

press the desired two-digit
location and

[ARM]

press

[ARM] alone to go to the next

sequential location

7

Exit

programming

enter your Installer Code
and press

[ARM]

a long beep will confirm your actions