4

Summary of User’s Commands

This page, called a

Command

Summary, is intended to give you
brief summaries of common
system operations. More detailed
explanations and related
information can be found within, by
referring to the user manual.

FUNCTION

PROCEDURE

System Arming

[USER CODE] + [ARM]

Stay Home Arming

[USER CODE] + [STAY]

Instant Stay

[STAY] + [STAY]

System Disarming

[USER CODE]

Duress Disarming

[DURESS CODE]

Silencing an Alarm

[USER CODE]

Bypassing / Unbypassing a

Zone

[

Q ] + [ 1 ] + [USER CODE ] + [ ZONE NUMBER TO BE

BYPASSED / UNBYPASSED]

Quick Bypassing Zone

[ ZONE NUMBER TO BE BYPASSED ] for at least 2 seconds

Reset Smoke Detector(s)

[

Q ] + [ 2 ] + [USER CODE ] + [UTILITY OUTPUT NUMBER

which is responsible for resetting the Smoke Detector]

Utility Output Operation

[

Q ] + [ 2 ] + [USER CODE ] + [ UTILITY OUTPUT NUMBER ]

Display Troubles

[

Q ] + [ 3 ]

Display Memory

[

Q ] + [ 4 ]

Setting/Changing
a User Code

[

Q] + [ 5 ] + [MASTER CODE] + [CODE NUMBER TO BE

SET/CHANGED] + [NEW CODE]

Set Date

[

Q ] + [ 6 ] + [ 1 ] + [MASTER CODE] + [MM] [DD] [YY]

Set Time

[

Q ] + [ 6 ] + [ 2 ] + [MASTER CODE] + [H][H] [M][M]

*Set Auto Arm Time

[

Q ] + [ 6 ] + [ 3 ] + [MASTER CODE] + [H][H] [M][M]

Set Follow-Me Phone No. 1

[

Q ] + [ 7 ] + [ 1 ] + [MASTER CODE] + Phone No. + [ #]

Set Follow-Me Phone No. 2

[

Q ] + [ 7 ] + [ 2 ] + [MASTER CODE] + Phone No. + [ #]

**Set Follow-Me Phone No. 3 [ Q ] + [ 7 ] + [ 3 ] + [MASTER CODE] + Phone No. + [ #]
**Set Follow-Me Phone No. 4 [ Q ] + [ 7 ] + [ 4 ] + [MASTER CODE] + Phone No. + [ #]
Maintenance:

On/Off Buzzer
On/Off Door Chime

*On/Off Audible Kiss-Off

Indication

[

Q ] + [ 8 ] + [MASTER CODE] + [1]

[

Q ] + [ 8 ] + [MASTER CODE] + [ 2]

[

Q ] + [ 8 ] + [MASTER CODE] + [ 3]

Get Event From Event

Logger

[

Q ] + [ 9 ] + [MASTER CODE] + [EVENT NO.]

Test System

[

Q ] + [ 0 ] + [MASTER CODE]

LED

Trouble

1

Low Battery

2

AC Power Loss

3

Clock Not Set

4

Communication Trouble

Trouble Table

5

Bell Loop Trouble

*New in Version 1.2

**New in Version 1.3

It is necessary to

ARM your system to

obtain protection from

intrusion.

All other forms of protection,
including

fire and 24-hour panic

alarms (i.e. police, fire, and medical)

are always ready to report alarms
and do NOT need to be armed.