Duress Code Follow (Latched)
UO is activated when any duress code is entered. The UO deactivates either when
arming the system or disarming the system due to an alarm that was activated from the
emergecy keypad keys, 24-hour zone violation or tamper zone violation.
25
Follow Chime (Pulse) (Ver. 1.2) UO is activated for several seconds whenever a
keypad sounds its chime.
26
Follow Bell Latched NO (Ver. 1.2) UO is activated whenever the bell is activated. UO
is deactivated at the bell cut-off time.
27
Follow Bell Latched NC (Ver.1.3)
28
Follow Ready NO (Ver.1.3) UO is activated whenever the system is in the ready state.
Locations: 22 23 24 25
COMMUNICATION PARAMETERS: LOCATIONS 26–29
Locations 26 and 27 allow you to define the manner in which the ORBIT-6 communicates with the
Central Station when it reports alarms, restorals, troubles, openings/closings, and tests.
Digital Communicator Controls: Location 26
•
First digit: determines the number (or hexadecimal digit) corresponding to the
Dialing Method / Duty Cycle / Redial Time desired
•
Second digit: determines the number corresponding to the
Attempts / Answering Machine Use / UL Installation
Attempts
Answering Machine
in Use
UL Installation
Voice Module
Attempts sets the
number of times the
ORBIT-6 will redial
the Central Station
after failing to
establish a
successful
communication.
If enabled to defeat an
answering machine, two
phone calls must be
made to the premises. On
the first call let the phone
ring once (by pushing the
space bar on the U/D
software keyboard). The
panel detects this ring
and starts a 60sec timer
during which the panel
will answer the next call
on the first ring.
If the ORBIT-6 is installed
in accordance with UL
requirements, for a
Residential Installation
(UL 1641), the operation of
the unit’s Digital
Communicator must be
modified so as to disable
features, which are
inappropriate.
If enabled (“YES”) voice
messages will be sent. If
“NO” then tones will be
used to represent an active
alarm.
Location: 26
Dialer Controls: (1
st
Digit):
1
st
Digit
Dialing Method
Duty Cycle
* Redial Central Station
8
DTMF
N/A
after 60 seconds
1
Pulse @ 20 pps
67/33
after 30 seconds
9
Pulse @ 20 pps
67/33
after 60 seconds
4 (default)
DTMF
N/A
after 30 seconds
5
Pulse @ 20 pps
61/39
after 60 seconds
D
Pulse @ 20 pps
61/39
after 60 seconds
3
Pulse @ 10 pps
67/33
after 30 seconds
B
Pulse @ 10 pps
67/33
after 60 seconds
7
Pulse @ 10 pps
61/39
after 30 seconds
F
Pulse @ 10 pps
61/39
after 60 seconds
*
redial refers to the number of seconds the ORBIT-6 will wait before redialing a busy or unresponsive Central Station
phone number.
UO1
Action
UO2
Action
UO3
Action
UO4
Action