PERIODIC TEST TIME: LOCATION 31

If desired, the ORBIT-6 can send a daily test transmission to the Central Station to verify the
operation of the unit’s Digital Communicator.

Location: 31

Periodic Test Time

Default: 0000

Sets a fixed, daily time for sending an ORBIT-6 test transmission to the Central Station. The
chosen time is expressed in 24-Hour format (following examples):
8:30 AM=0830

11:15AM=1115

4:30 PM=1630

If desired, disable the test transmission capability by
accepting (or entering) the default (0000)
Note: Failure to set the systems’ time clock, will prevent the
code from being sent to the Central Station.

COMMUNICATOR REPORTING CODES: LOCATIONS 32 THROUGH 86

To program the codes that will be transmitted by the ORBIT-6 to the Central Station.
To prevent the corresponding event from being reported, use a “double-zero” (00, the default) in
the location.

Reporting Codes for Alarm Events:

Location

Description

Digits

Default

Report Code

32

Zone 1 Alarm Reporting code

2

00

33

Zone 2 Alarm Reporting code

2

00

34

Zone 3 Alarm Reporting code

2

00

35

Zone 4 Alarm Reporting code

2

00

36

Zone 5 Alarm Reporting code

2

00

37

Zone 6 Alarm Reporting code

2

00

38

Zone 7 Alarm Reporting code

2

00

39

Zone 8 Alarm Reporting code

2

00

40

Keypad Fire Alarms Reporting code

2

00

41

Keypad Panic Reporting code

2

00

42

Keypad Special Emergency Reporting code

2

00

Notes on Alarm Restorals

An ORBIT-6 Restoral Report informs the Central Station that the external sounder’s operation,
initially triggered by the respective alarm condition, has either “timed out” or been silenced by the
act of system disarming. Be sure to check with Central Station personnel if restorals are
permitted and, if so, what codes are required.

Restoral Codes

Location

Description

Digits

Default

Report Code

43

Zone 1 Restoral Code

2

00

44

Zone 2 Restoral Code

2

00

45

Zone 3 Restoral Code

2

00

46

Zone 4 Restoral Code

2

00

47

Zone 5 Restoral Code

2

00

48

Zone 6 Restoral Code

2

00

49

Zone 7 Restoral Code

2

00

50

Zone 8 Restoral Code

2

00

51

Keypad Fire Restoral Code

2

00

52

Keypad panic Restoral Code

2

00

53

Keypad Special Emergency Restoral Code

2

00

Periodic