Installer manual 15, System codes: locations 06-10 – Orbit Manufacturing Rokonet ORBIT-6 RP-206 User Manual

Page 15

Advertising
background image

Installer Manual

15

Location: 04 Callback UD Phone #

Enables greater security for remote Upload/Download operation. This is a number to
which the alarm company computer, equipped with the U/D software, will be
connected.

When a call is made from a computer, using U/D software, to the Orbit-6 panel, the
system will hang-up and call back using this UD phone number. Up to 24 digits can be
entered into the U/D phone number, include all the digits and functions as above in
Location 02. To delete an existing phone number press #.

Location: 05 Account Number

Default: 0000

PURPOSE: to assign the system’s Central Station Account Number
hexadecimal account numbers (those using 0 through 9 and A through F) are
accepted by the

ORBIT-6; use the key combinations below to enter hexadecimal digits

“A” through “F”:

“0” will not send a digit to the central station, to send “0” use “A” digit

SYSTEM CODES: LOCATIONS 06-10

Location: 06

Access Code

Default: 5678

PURPOSE: to provide data security during Upload/Download operations
this same Access Code must subsequently be entered into the corresponding account
profile in the Upload/Download software (along with the Remote ID codes, see
Location 07, below).

Location: 07

Remote ID Code

Default: 0001

PURPOSE: to provide data security during Upload/Download operations this same
Remote ID Code must subsequently be entered into the corresponding account profile
in the Upload/Download software.

Location: 08

Installer Code I

Default: 0206

PURPOSE: the installer code is used by alarm company personnel authorized to
modify the system’s parameters It is recommended to change the “factory default”
Installer Code to one of your own choice.

hex digit

press

hex digit

press

A

[STAY], 1

D

[STAY], 4

B

[STAY], 2

E

[STAY], 5

C

[STAY], 3

F

[STAY], 6

Acct No.

Access Code

Remote ID

Installer Code

Advertising