Codabar settings, Enable/disable codabar, Send start/stop characters – Omnitron Systems Technology RS-232 User Manual

Page 26: Check digit

Advertising
background image

20

Codabar Settings:

Enable/Disable Codabar

If enabled, Codabar symbology will be read, subject to the reading restric-

tions specified by this set of options. If disabled, the data from the symbology

will be disregarded.

SELECTION CODE: F5

Codabar Enable

A

Codabar Disable

B

Send Start/Stop Characters

Codabar uses the A, B, C, and D characters as Start and Stop characters, giv-

ing 16 unique Start/Stop character combinations. Some applications require

that these characters be transmitted with the data while others specify that

they must not be sent.

SELECTION CODE: F5

Send Start/Stop

C

Do Not Send Start/Stop

D

Check Digit

When Check Digit is selected, the reader takes the last character in the de-

coded data stream as a check digit. It then calculates the correct check digit

for the remaining data and compares it to the last data character. If it is the

same, the data is accepted. If not, the data is rejected. With the Calculate and

Send Check Digit option, the reader will send the check digit as part of the

data stream. If the Calculate but Do Not Send Check Digit option is selected,

the reader will strip it from the data stream before transmission. If the Check

Digit is not calculated, the reader will assume the last data character read

from the symbol is part of the data stream and will not make a comparison

test.

SELECTION CODE: F5

Do Not Calculate Check Digit but Send Whole Data Stream

E

Calculate and Send Check Digit

F

Calculate but Do Not Send Check Digit

G

Advertising