Reviewing configuration settings, Track two send accout number only, Track separator – Omnitron Systems Technology RS-232 User Manual
Page 34

28
Track Two Send Accout Number Only
Track Two of a magnetically encoded credit card includes the account number
information as well as other information. If this option is selected, all other-
data contained on the track is suppressed before transmission.
SELECTION CODE: H3
Track 2 Send Account Number Only
A
Track 2 Not Limited to Account Number
B
Track Separator
One character from the Full ASCII Table: This option allows the user to select
the character used to separate data decoded from each track when using mul-
tiple track magnetic stripe readers.
H4<ENTER><SELECTED CHARACTER><ENTER>
Note: For no track separator, enter N. Default is <ENTER>.
Reviewing Configuration Settings
The reader’s current settings can be reviewed by following these steps:
1. Locate the group that contains the settings you want to review.
2. On an AT-compatible computer, enter any communication program. (Hyper
Terminal is recommend in the Windows environment.)
3. Enter the setup mode for that group by typing /E/D/FX <Enter>. (X in this
case is the single alpha character identified with the group located in Step 1.)
4. The reader will respond with two beeps after <ENTER> is depressed.
5. Review the settings for the group by typing XY<ENTER>. (X is the same
single alpha character as typed in Step 3.)
6. After <ENTER> is depressed, the reader will display the current settings
for the group onto the screen for user to review, followed by two beeps from
the reader. *
7. Exit the setup mode after reviewing the settings by typing XZ <ENTER>.
(X is the same single alpha character as typed in Step 3.)
8. The reader will respond with four beeps.
* Hyper Terminal must be configured correctly: Append Line Feed to Incoming Line
End.