Examples – Omnitron Systems Technology RS-232 User Manual
Page 47

41
5. If UNMATCHED INPUT is set to SEND, the unmatched data is passed on
to the message processing section of the reader, where any previously-defined
postamble, preamble, and terminator characters are added before the data is
sent to the output port.
Examples
EXAMPLE ONE
76440057320712
Symbology Code 128
Desired Output: Divide the input data record into two fields with one consist-
ing of the first six digits and the second containing the remaining data. The
output should have a <CARRIAGE RETURN> or <CR> inserted after each
field.
Formula
ID h C 06 A <ENTER> SEND ACBC
Field List
Field A 764400
Field B 57320712
Field C <CR>
Keystroke Sequence
Enter Data Editing Setup
/E/D/FJ<ENTER>
Enable Data Editing
JA<ENTER>1<ENTER>
Enter Code ID as h (for Code 128)
JC<ENTER>h<ENTER>
Define first six characters as Field A,
and remaining data as Field B
JF<ENTER>0<ENTER>
6<ENTER>
Enter Add Field C as the <ENTER> key
JJ<ENTER>^N<ENTER>*
Define Field Sending Sequence of ACBC JK<ENTER>A<ENTER>
C< ENTER>B<ENTER>
C<ENTER>
Save Exit Setup
JZ<ENTER>
Output Data
764400<CR>
57320712<CR>
* ^N: Do a CTRL-N by holding down the <CTRL> key while pressing the N key, then
releasing both.