Examples – Omnitron Systems Technology RS-232 User Manual

Page 47

Advertising
background image

41

5. If UNMATCHED INPUT is set to SEND, the unmatched data is passed on

to the message processing section of the reader, where any previously-defined

postamble, preamble, and terminator characters are added before the data is

sent to the output port.

Examples

EXAMPLE ONE

76440057320712

Symbology Code 128

Desired Output: Divide the input data record into two fields with one consist-

ing of the first six digits and the second containing the remaining data. The

output should have a <CARRIAGE RETURN> or <CR> inserted after each

field.

Formula

ID h C 06 A <ENTER> SEND ACBC

Field List

Field A 764400

Field B 57320712

Field C <CR>

Keystroke Sequence

Enter Data Editing Setup

/E/D/FJ<ENTER>

Enable Data Editing

JA<ENTER>1<ENTER>

Enter Code ID as h (for Code 128)

JC<ENTER>h<ENTER>

Define first six characters as Field A,

and remaining data as Field B

JF<ENTER>0<ENTER>

6<ENTER>

Enter Add Field C as the <ENTER> key

JJ<ENTER>^N<ENTER>*

Define Field Sending Sequence of ACBC JK<ENTER>A<ENTER>

C< ENTER>B<ENTER>

C<ENTER>

Save Exit Setup

JZ<ENTER>

Output Data

764400<CR>

57320712<CR>

* ^N: Do a CTRL-N by holding down the <CTRL> key while pressing the N key, then
releasing both.