Data Editing Commands

1. Enter DATA EDITING mode by typing /E/D/FJ

2. Press <ENTER>. The reader should beep twice.

3. Type the two-character selection code for the function you wish to enable

or set.

4. Press <ENTER>. The reader should beep twice.

5. Type the command you wish to enter.

6. Press <ENTER>. The reader should beep twice.

7. Continue to add commands to the data editing formula as desired.

8. Save the formula and exit the data editing mode by typing

JZ <ENTER>. The reader should beep four times.

Note: JZ should only being entered at the end of the entire data editing formula, not

after each command. See examples page 41.

Data Editing On/Off

Use this command to turn the Data Editing function on or off.

SELECTION CODE: JA

Data Editing Off

0

Data Editing On

1

EXAMPLE:

To turn the Data Editing function on, enter:

/E/D/FJ<ENTER>JA<ENTER>1<ENTER>...

Unmatched Input Send/Do Not Send

This command enables or disables the transmission of data that does not

meet the restrictions of the data editing formula(s). When SEND ALL DATA

is selected, data that does not match any of the formulas will be transmitted

anyway, along with any preambles or postambles. When DO NOT SEND is

selected, unmatched data will not be sent.

SELECTION CODE: JB

If No Formula Matches Data,

0

Do Not Send Data

If No Formula Matches Data,

1

Send All Data