64

Unit Installation

Section 3-2

Example: Using the C200HW-PA204 Power Supply Unit supplying a maxi-
mum current of 4.6 A (5 V) and maximum power of 30 W.

CQM1H-series PLCs

Only one Controller Link Unit can be connected in a CQM1H-series PLC.
Connect the Controller Link Unit to the left side of the CPU Unit and then con-
nect the Power Supply Unit to the left of the Controller Link Unit.

After the Units have been connected, secure them with the slide locks on the
top and bottom of the Units.

Note The CQM1H-CLK21 Controller Link Unit can be connected only to the

CQM1H-CPU51/61 CPU Unit. It cannot be connected to the CQM1H-CPU11/
21 CPU Unit.

3-2-2

Mounting a Repeater Unit

Repeater Units can be either mounted on a DIN Track or screw-mounted.

Name

Model

Current consumption

per Unit (A)

Number of

Units

Current consumption

(A)

CPU Backplane (8 slots)

CS1W-BC083

0.11 A

1

0.11 A

CPU Unit

CS1H-CPU67H

0.82 A

1

0.82 A

Controller Link Unit (Optical)

CS1W-CLK21-V1

0.33 A

8

2.64 A

Total

3.57 (power consump-
tion: 17.85 W)

CPU Backplane

Expansion CPU
Backplane

3/5/10 slots

11 slots

CPU
Unit

Of these
14, 16, or
21 slots,
installa
tion is
possible
in up to 4
slots.

Power Supply Unit

CQM1H-CLK21
Controller Link Unit

CQM1H-CPU51/61
CPU Unit