Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11

16

B. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).

Clearance to combustible material under the insert is 3/8
inch (10 mm). Clearance from sides of fi replace opening
to combustibles is 12 inches (305 mm). Clearance from
top of fi replace opening for combustibles extending 1 inch
to 8 inches max. is 14 inches.

• Use leveling legs to raise insert minimum 3/8 inch (10

mm) above combustible material or outer wrap of factory
built fi rebox.

Combustible facings must not extend behind the insert
surround.

Figure 5.2

Model

A

B

C

D

Hudson Bay Insert

Inches 14

11

12

7

Millimeters

356

279

305

178

Underneath bottom of appliance to combustibles: 3/8 in. (10 mm)

16 in. (406 mm) front floor protection required 0 in. to 2-1/2 in. (64 mm) below bottom of appliance. (1/2 in. of "k" = .84)

No floor protection needed if 2-1/2 in. (64 mm) or greater from bottom of appliance.

To 8 in. (203 mm ) Deep mantel:
14 in. (356 mm) From top of insert

A

B

D

C

SIDE WALL

HEARTH

1-1/2 in. (38 mm)

16 in. (406 mm)