Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11

NOTICE: DO NOT wire 110 VAC to the millivolt valve! This
will damage the valve.

ON/OFF Switch

• An ON/OFF switch is included with appliance and should

be attached to surround/facing.

• If desired an additional wall switch, thermostat, or remote

control may be added to system as shown in Figure

10.1).

• If using a thermostat use one compatible with a millivolt

gas valve system:

- Install the thermostat in the location as indicated in the

thermostat instructions to ensure proper operation of
appliance.

- Use low resistance thermostat wire for wiring from

ignition system to the wall switch and thermostat.

- Keep wire lengths short as possible by removing any

excess wire length.

- Use the following chart for wire sizing.

A. Wiring Requirements

NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with
National Electric Code
ANSI/NFPA 70-latest edition
or the Canadian Electric
Code CSA C22.1.

• A 110-120 VAC circuit for this product must be protected

with ground-fault circuit-interrupter protection, in compliance
with the applicable electrical codes, when it is installed in
locations such as in bathrooms or near sinks.

• Low voltage and 110 VAC voltage cannot be shared

within the same wall box.

WARNING! Risk of Shock or Explosion! DO NOT wire
110V to the valve or to the appliance wall switch. Incorrect
wiring will damage controls.

10

10

Electrical Information

Figure 10.1 Standing Pilot Ignition Wiring Diagram

ROCKER SWITCH / WALL THERMOSTAT / REMOTE

VARIABLE REGULATOR

PILOT ADJUSTMENT CAP

MANIFOLD PRESSURE

INLET PRESSURE

PUSH BUTTON IGNITOR

THERMOPILE

IGNITOR

PILOT

THERMOCOUPLE

Do not connect this appliance to a thermostat serving
any other appliance.

Bedroom installation in Canada requires this appliance
to be connected to a thermostat.

Wire Size

Max. Length

16 gauge

65 feet

18 gauge

40 feet

20 gauge

25 feet

22 gauge

18 feet

B. Standing Pilot Ignition System Wiring

• The standing pilot ignition system wiring DOES NOT

require a 110 VAC supply to operate.

• A 110 VAC junction box may be installed for use of a fan

or remote control. Keep wire lengths short as possible.
The supplied power cord may be routed out onto the
hearth to a nearby outlet.