Quadra-Fire HUDBAY-INS 7008-115 User Manual

Page 35

Advertising
background image

35

Quadra-Fire • HUDBAY-INS • 7008-115 Rev. o • 8/11

L. Fixed Glass Assembly

Removing Fixed Glass Assembly

WARNING! Risk of Asphyxiation! Handle fi xed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.

DO NOT strike, slam or scratch glass.

DO NOT operate fi replace with glass removed, cracked,

broken or scratched.

Replace as a complete assembly.

Open lower access panel. Pull out and unhook the two
spring latches on the bottom of the appliance that secure
the door.

Rotate the door forward approximately 1-1/2 in. (38 mm).
Holding the ashlip, lift the door up off of the stationary
latches and away from the appliance.

Replacing Fixed Glass Assembly

• Door Frame with Glass Assembly Replacement

Use only Door Assembly replacement, as specifi ed in

Section 14 of this manual, available from your dealer,
if any glass becomes broken in the Hudson Bay Insert.

Follow the previous instructions to install the door crown

and grille to the new Door Assembly.

Figure 12.27

STATIONARY LATCHES

STATIONARY LATCHES

SPRING LOADED LATCHES

SPRING LOADED LATCHES

Advertising