Quadra-Fire QVI-30FB User Manual

Page 14

Advertising
background image

Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07

14

Figure 4.

This option shows both exhaust and inlet
air vent pipes attached to the adaptor.

WARNING: THE EXHAUST VENT PIPE MUST
ONLY BE CONNECTED TO THE EXHAUST
STARTING COLLAR OF THE UNIT AND THE
CENTER COLLAR OF THE TERMINATION CAP.

A 3 FOOT SECTION OF STAINLESS STEEL
FLEXIBLE LINER MUST BE ATTACHED
DIRECTLY TO THE EXHAUST COLLAR ON
COLLAR SLIDE PLATE.

!

THE INLET AIR PIPE MUST ONLY BE
CONNECTED TO THE INLET AIR COLLAR OF
THE UNIT AND EITHER ATTACHED TO THE
INLET AIR COLLAR OF THE TERMINATION CAP
OR TERMINATED IN THE CHIMNEY.

!

!

TERMINATION

CAP

EXHAUST

VENT PIPE

V= 14 FT. MINIMUM

50FT. MAXIMUM

3 INCH COLLAR

(Factory installed to

stainless steel section)

WARNING: DO NOT

BLOCK PIPE END WITH

INSULATION OR ANY OTHER

SEALING MATERIAL

STAINLESS STEEL

PIPE - 3 FT. MIN.

REQUIRED (INCLUDED)

SEAL DAMPER

AREA

COLLAR ATTACHMENT

BRACKET

EXHAUST COLLAR

INLET AIR COLLAR

INLET AIR

VENT PIPE

FLASHING