Step 5. gas pressure requirements, Step 6. wiring the fireplace – Quadra-Fire QVI-30FB User Manual

Page 17

Advertising
background image

Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07

17

Step 5. Gas Pressure Requirements

Pressure requirements for these gas appliances are shown
in the table below.

Pressure

Natural Gas

Propane

Minimum

5.0 inches

11.0 inches

Inlet Pressure

w.c.

w.c.

Maximum Inlet

14.0 inches

14.0 inches

Gas Pressure

w.c.

w.c.

Manifold

3.5 inches

10.0 inches

Pressure

w.c.

w.c.

Inlet and outlet pressure taps are provided on the front face
of the gas control for a test gauge connection to measure
the manifold pressure. Use a small flat blade screwdriver to
crack open the screw in the center of the tap. Position a
rubber hose over the tap to obtain the pressure reading.

THE FIREPLACE AND ITS INDIVIDUAL SHUT-OFF
VALVE MUST BE DISCONNECTED FROM THE GAS
SUPPLY PIPING SYSTEM AND ISOLATED DURING ANY
PRESSURE TESTING OF THE SYSTEM AT TEST
PRESSURES EQUAL TO OR IN EXCESS OF ONE-HALF
(1/2) PSIG (3.5 KPA).

NOTE: Electrical wiring must be installed by a li-
censed electrician.

CAUTION: DISCONNECT REMOTE CONTROLS IF AB-
SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE-
VENT ACCIDENTAL APPLIANCE OPERATION.

For Standing Pilot Ignition Wiring
Appliance Requirements

Wall Switch

Position the wall switch in the desired position on the wall.
An assembly of 18 ft of 20 AWG is provided with the appli-
ance to connect the wall switch to the appliance. Instead of
the supplied assembly, wire with a length of 25 ft or less and
a gauge of 20 AWG through 14 AWG is acceptable. The
wire needs a jacket with a temperature rating of 140

o

F (60

o

C)

or higher. At the appliance connect the wire to the ON/OFF
switch pigtails.

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER SERVICING.

Figure 8.

Standing Pilot Ignition Wiring Diagram

THERMOCOUPLE

GAS

VALVE

OPTIONAL WALL SWITCH

THERMOSTAT OR REMOTE

ON

OFF

ROCKER

SWITCH

THERMOPILE

WHITE T2

RED T1

!

WARNING: DO NOT CONNECT 110-120 VAC
TO THE GAS CONTROL VALVE OR THE WALL
SWITCH OR THE APPLIANCE WILL MALFUNC-
TION AND THE VALVE WILL BE DESTROYED
.

Step 6. Wiring the Fireplace

This appliance REQUIRES 110-120 VAC to operate. It is
equipped with a blower.

!

WARNING: MUST USE THE CORD SUPPLIED
WITH THE J-BOX.

Use of the electrical junction box provided is required if
using a blower or remote. Plug the cord into a convenient
outlet. An electrician may install an outlet box inside the
fireplace. Place the outlet in the lower, back corner of the
fireplace. Make sure fan doesn’t touch back wall. Optional
remote controls are available and should be installed along
the side of the insert (see Step 2. Positioning, Leveling and
securing the Insert).