Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07

18

Serving the blower

On units already installed removal of decorative front, sur-
round and gas insert is required.

• Detach flexible liner from the top of unit.

• Remove the four screws on the coverplate (see Figure 11).

• Bend up the tabs on the base pan (see Figure 10).

Figure 9.
Junction box installation

Figure 10. Fan Wiring Diagram

Figure 11.

NOTE: IF ANY OF THE ORIGINAL WIRE AS SUP-
PLIED WITH THE APPLIANCE MUST BE RE-
PLACED, IT MUST BE REPLACED WITH TYPE
105

0

C RATED WIRE.

JUNCTION BOX

VARIABLE SPEED CONTROL

TEMPERATURE

SENSOR SWITCH

WHT

GRN

BLK

BLK

110-120 VAC

BLOWER

BLOWER RECEPTACLE

BLK

BLK

BLK

BLK

WHT

GROUND

WHT

BLK

BLK

BLK

REMOTE

RECEPTACLE

FAN

COVER

PLATE

GROUND

WIRE

JUNCTION

BOX

SIDEWALL

FEED PLUG

THROUGH HOLE

INSERT STRAIN RELIEF

AROUND CORD IN THIS END

FROM OUTSIDE OF UNIT

SCREW

PROVIDED

To service or clean:

• Remove the ground wire of the fan can clip on the side of

the base pan.

• Remove the blower in between the bend up tabs.

• Install and wire the blower per instruction shipped with

the fan.

• Reinstall the blower in reverse order. Make sure the fan

does not make contact with the back wall.

FAN

TEMPERATURE

SENSOR SWITCH

SPEED CONTROL

(RHEOSTAT)

JUNCTION

BOX

GROUND WIRE

(ATTACH TO ANY

METAL SURFACE)

BEND UP

TABS

REMOTE

OUTLET

FAN

OUTLET