Toshiba Qosmio Personal Computer X500 User Manual

Page 131

Advertising
background image

Test Program for Field.

Subtest 02

Backup Memory

This subtest writes 50 bytes of test data (FFH, AAH, 55H, and 00H) to the
CMOS 14

th

address, then reads the new data and compares it to the original

data.

Subtest 03

Real Time Carry

CAUTION: When this subtest is executed, the current date and time are
reset.

This subtest checks the clock’s carry function.

[ REAL TIME CARRY TEST ]

Current date : 12-31-1999

Current time : 23:59:55


Press [Enter] key to exit test


The following is the display after the date carry function is executed.

[ REAL TIME CARRY TEST ]

Current date : 01-01-2000

Current time : 00:00:01

Press [Enter] key to exit test



To exit this subtest and return to the Real Time Clock menu:


Press

Enter if NO was selected for Test Loop on the Test Parameter Menu.

Press

Ctrl + break if YES was selected for Test Loop on the Test Parameter

Menu.

46

Qosmio X500

Maintenance Manual (960-Q08)

Advertising