Vi/ii speed, Frequency setpoint #1 on pg. 134, Vi/ii speed frequency setpoint #1 on pg. 134 – Toshiba W7 User Manual

Page 140: V/f pattern, Vi/ii speed frequency setpoint #1, Vector motor model slip frequency gain

Advertising
background image

134

W7 ASD Installation and Operation Manual

Vector Motor Model Slip Frequency Gain

Program

⇒

Motor Settings

⇒

Vector Motor Model Slip Frequency

Gain

This parameter provides a degree of slip compensation for a given load. A
higher setting here decreases the slip allowed for a given load/ASD output ratio.

Parameter Type — Numerical

Factory Default — 0.60

Changeable During Run — Yes

Minimum — 0.00

Maximum — 2.55

V/f Pattern

Program

⇒

Fundamental Parameters

⇒

Fundamental #1

⇒

V/f Pattern

This function establishes the relationship between the output frequency and the
output voltage.

Settings:

Constant Torque
Variable Torque

Parameter Type — Selection List

Factory Default — Variable Torque

Changeable During Run — No

VI/II Speed Frequency Setpoint #1

Program

⇒

Frequency Settings

⇒

Speed Reference Setpoints

⇒

VI/II

⇒

VI/II Speed Frequency Setpoint #1

This parameter is used to set the gain and bias of the VI/II input terminal when
the VI/II terminal is used as the control input while operating in the Speed
Control
mode.

Note: See note on

pg. 33

for further information on the VI/II

terminal.

VI/II Input Speed Control Setup

Perform the following setup to allow the system to receive Speed control input
at the VI/II input terminal:

• Program

⇒

Utilities ⇒ Command and Frequency Settings ⇒ Command

Mode Select

⇒

Terminal Block.

• Program

⇒

Utilities ⇒ Command and Frequency Settings ⇒ Frequency#1

Mode Select

⇒

VI/II.

• Provide a Run command (F and/or R).

Speed Control

Perform the following setup to allow the system to perform Speed control from
the VI/II input terminal:

• Set VI/II Speed Frequency #1,

• Set the VI/II input signal level (VI/II Speed Ref #1) that represents VI/II

Speed Frequency #1,

• Set

VI/II Speed Frequency Setpoint #2

, and

• Set the VI/II input signal level (VI/II Speed Ref #2) that represents

VI/II

Speed Frequency Setpoint #2

.

Once set, as the VI input voltage or the II current changes, the output frequency
of the ASD will vary in accordance with the above settings.

This parameter sets VI/II Speed Frequency #1 and is the frequency that is
associated with the setting of

VI/II Speed Reference Setpoint #1

when

operating in the Speed Control mode.

Parameter Type — Numerical

Factory Default — 0.0

Changeable During Run — Yes

Minimum — 0.0

Maximum — Max. Freq.

Units — Hz

Frequency Settings

Vector Motor Model Slip Frequency Gain

VI/II Speed Frequency Setpoint #1

Advertising