2 500-02 series talkback controller card – Trilogy Touch Technology Trilogy Commander Digital Intercom 9 User Manual

Page 12

Advertising
background image

Commander Installation Guide

Page

12

of

81

Issue 9

Trilogy Communications Limited

2.4.2 500-02 SERIES TALKBACK CONTROLLER CARD

There are currently two versions of the Talkback Controller: -.

• 500-02-11, which has on-board Flash Ram fitted at all times
• 500-02-12, which updates the 500-02-11 and provides improved serial communication.

They are fitted to the 500-08 (above). Initially, only fit the lower 500-02 Talkback Controller.
The upper card is used for fault tolerant (redundant) operation if this option has been
ordered.

The diagram below shows component layout of the 500-02-11 and -12.

The following key points should be noted:

• The flash bank selector control knob located on the front of the 500-08 series

changeover card is inoperative with the 500-02-1x Talkback Controller. The PCB
mounted rotary switch located on the front edge of the module itself selects the boot
flash bank.

• In fault tolerant (redundant controller) systems fitted with the 500-02-1x Talkback

Controller, main and standby controllers in Frame 1 must be selected to the same
boot flash bank (i.e. position 1,2,3 or 4 on the front rotary switch).

• In multi-frame systems, in frames other than Frame 1, the flash bank selector switch

should be set to position 6.

• Setting the flash bank selector switch to position 5 on Frame 1 causes the system to

start without loading a configuration.

• If 500-01-10 TDM controllers are fitted, they "notify" their frame position to the

Talkback Controllers. Thus, for a multi-frame system, the Flash Bank Selector switch
setting in frames other than Frame 1 is irrelevant.

• The operation of the LEDs on the 500-02 series Talkback Controller is described in

the Commander Technical Manual.

500-02-11

Flash Re-
program socket

Flash boot
selector switch

Reset

Advertising