8.5.4.4 500-3x-3x Series Expansion panel interconnection cables

Type A (max. length 10 metre)

D9 Free Plug -
Pin

Function

Function

D9 Free Plug -
Pin

4

Transputer
Data out +

Pair 1

Transputer
Data in +

4

8

Transputer
Data out -

Transputer
Data in -

8

5 Transputer

Data In +

Pair 2

Transputer
Data out +

5

9 Transputer

Data In -

Transputer
Data out -

9

3 Ground

Ground

3

Type B (max length 10 metres)

D9 Free Plug -
Pin

Function

Function

D9 Free Plug -
Pin

4

Transputer
Data out +

Pair 1

Transputer
Data in +

5

8

Transputer
Data out -

Transputer
Data in -

9

5 Transputer

Data In +

Pair 2

Transputer
Data out +

4

9 Transputer

Data In -

Transputer
Data out -

8

3 Ground

Ground

3

8.5.5 CONNECTING VIA STRUCTURED CABLING

All control panel types may be connected to the matrix by Category 5 structured cabling
systems. Suitable adaptors are available from most electronic component distributors. The
RS part numbers are listed below.

Panel Connection: RJ45 to D9 socket. RS 818-700

Matrix Connection: RJ45 to D9 plug. RS 818-693

As supplied, these adaptors require the pins to be inserted into the D type housing. Use the
following table as a guide. The colour codes may not be correct for other brands.

D9 pin

RJ 45 pin

Colour (see above)

1

No connection

No connection

2 2

Yellow

3 6

Brown

4 4

Red

5 8

Blue

6 1

Black

7 3

Orange

8 5

Green

9 7

Grey