8.5.4 500-40-0X SERIES EXPANSION PANELS

Control Panels may be linked together to provide additional facilities at one operating
position. Additional level controls (RENs) or switches may be added. Alternatively, two
standard panels from the 500-30 series may be linked together and will only utilise a single
matrix port.

The following detail refers to expansion panel types:

• 500-40-00

8 way encoder panel

• 500-40-01

12 way encoder panel

• 500-40-02

15 key switch panel

• 500-40-04

32 way encoder panel

An installation specification is given below.

Dimensions

485mm wide x 44.5mm high x 100mm deep
(excluding connectors) 150mm deep (maximum
including mating connectors)

19” x 1RU rack mounting

Mains Input

90 – 260 V ac, 50-60Hz

Current Consumption

150mA @ 90V ac, 50mA @ 250V ac.

8.5.4.1 Connector Pin Out

Expansion In - D9 Fixed Socket

Pin

Function

1 Analyse

Input

2

Enable Remote Boot

3 Ground
4

Transputer Link Out +

5

Transputer Link In +

6 Error

signal

Out

7 Reset

In

8

Transputer Link Out-

9

Transputer Link In-

Test Port– D9 Fixed Socket

Pin

Function

1 Analyse

Input

2

Enable Remote Boot

3 Ground
4

Transputer Link Out +

5

Transputer Link In +

6 Error

signal

in

7 Reset

Out

8

Transputer Link Out-

9

Transputer Link In-

Expansion Out– D9 Fixed Socket

Pin

Function

1 Analyse

Input

2

Enable Remote Boot

3 Ground
4

Transputer Link Out +

5

Transputer Link In +

6 Error

signal

in

7 Reset

Out

8

Transputer Link Out-

9

Transputer Link In-

Advertising