9 500-31-60 standard facility 16 key control panel, 1 specification, Rear panel layout – Trilogy Touch Technology Trilogy Commander Digital Intercom 9 User Manual

Page 46: Panel. see section 5.9

Advertising
background image

Commander Installation Guide

Page 46 of 81

Trilogy Communications Limited

Issue 9

5.9 500-31-60 STANDARD FACILITY 16 KEY CONTROL PANEL

The 500-31-60 panel provides 16 programmable lever keys in a 2U rack mount chassis. For
information on programming the software driven “cut switch” operation, see section 10.3.

5.9.1 SPECIFICATION

Dimensions

485mm wide x 88.9mm high x 80mm deep
(approx. including PSU and mating connectors).
19” x 2RU rack mounting

Mains Input

90 – 250 V ac, 50-60Hz

Current Consumption

150mA @ 90V, 50mA @ 250V

5.9.2 REAR PANEL LAYOUT

Connector types:

Matrix

RJ 45 socket

GPIO

D9 Fixed Socket

Audio I/O

D15 Fixed Socket

Footswitch

D9 Fixed Socket

Matrix – RJ-45 fixed socket on panel

RJ-45
Pin

Function

1

Panel Data out +

Pair
1

2

Panel Data out -

3

Panel Data In +

Pair
2

6

Panel Data In -

5

Panel Audio out +

Pair
3

4

Panel Audio out -

7

Panel Audio in +

Pair
4

8

Panel Audio in -

Cable

Screen

Headset - 5 Pin XLR Fixed Socket (front
panel)

Pin

Function

1

Mic IN (Screen)

2 Mic

IN

3

Headset Gnd

4 Headset

Out

5 Headset

Out

Foot Switch - D9 Fixed Socket

Pin

Function

1

Foot Switch Input

2 No

Connection

3 Chassis

Ground

4

Reserved

5

Reserved

6 Ground
7

Reserved

8

Reserved

9

Reserved

Advertising