If at any time during the subsequent transmissions the alarm condition is evaluated
as “false”, then the alarm will be reset and email transmissions for this alarm will stop
(until the next time the alarm is triggered, of course).

Subject: Enter a string of up to 128 characters in length which will appear in the
“subject” line of the alarm email. The body of the alarm email is empty.

10.9.4 Submitting Changes

Whenever any of the Alarm configuration elements (alarm settings or email
configuration parameters) have been changed, the “submit” button located in the
lower right-hand portion of the web page must be clicked in order to write these
settings to the interface card’s filesystem.

Note that because these configuration elements are read from the filesystem only
when the interface card boots up, the act of submitting configuration changes will
also reset the interface card. Please allow 30 seconds for the interface card to
reboot, at which time it will then be operating with the recently-submitted
configuration. Refer to Figure 45.

Figure 45: Submit Configuration Changes