Vizio rp56 user guide, Status leds – Vizio RP56 User Manual

Page 51

Advertising
background image

VIZIO RP56 User Guide

040330 48

Status LEDs

There are two status LEDs on the front of the DLP TV.

Normal Operation

State

Power LED

Lamp LED

Description

AC off

Not lit

Not lit

AC power not connected

Standby mode

Green

Not lit

AC power is connected and the DLP TV is
in standby mode.

Warm-up/Cool down
mode

Green

Flashing

AC power is connected and the power
button has just been turned on or off.

Operation mode

Green

Green

AC power is connected, the power button
has been pressed and the lamp has
warmed up.

Error Codes

Error Code

Power LED

Lamp LED

Description

21 Flashes

green

twice, then
orange once.

Not lit

One of the cooling fans has failed. See
"support" on page 51.

32 Flashes

green

three times,
then orange
twice.

Flashing

Indicates lamp trouble or failure. The DLP
TV will automatically shut down and restart
itself. If this does not solve the problem,
see "support" on page 51.

52 Flashes

green

five times,
then orange
twice.

Not lit

Indicates hardware error. Power off the
DLP TV, wait one minute, and then restart
the DLP TV. If this does not solve the
problem, see "support" on page 51.


Advertising