Owner’s manual, Inspecting burners, Operating heater – Vanguard Managed Solutions PRVYS18PWA User Manual

Page 17: Continued

Advertising
background image

17

104343

OWNER’S MANUAL

INSPECTING
BURNERS

Check pilot flame pattern and burner flame
patterns often.

PILOT FLAME PATTERN

Figure 26 shows a correct pilot flame pat-
tern. Figure 27 shows an incorrect pilot
flame pattern. (

Note:

Appearance of pilot

assembly may vary by model.) The incor-
rect pilot flame is not touching the thermo-
couple. This will cause the thermocouple to
cool. When the thermocouple cools, the
heater will shut down.

If pilot flame pattern is incorrect, as shown
in Figure 27

• turn heater off (see To Turn Off Gas to

Appliance, manually controlled models,
page 16. Thermostatically controlled
models, this page, column 2).

• see Troubleshooting, pages 18 through 20.

Thermocouple

Pilot Burner

Figure 26 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 27 - Incorrect Pilot Flame Pattern

MAIN BURNER

Periodically inspect all burner flame holes
with the heater running. All slotted burner
flame holes should be open with yellow
flame present. All round burner flame holes
should be open with a small blue flame
present. Some burner flame holes may be-
come blocked by debris or rust, with no
flame present. If so, turn off heater and let
cool. Either remove blockage or replace
burner. Blocked burner flame holes will
create soot.

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation on page 16. If you don’t
smell gas, go to the next step.

5.

Turn control knob counterclockwise

C-clockwise

to the PILOT position.

Press in control knob for five (5) sec-
onds (see Figure 24, page 16 ).

Note:

You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds or less. This will allow
air to bleed from the gas system.
• If control knob does not pop out

when released, contact a qualified
service person or gas supplier for
repairs.

6.

With control knob pressed in, press
and release ignitor button. This will
light pilot. The pilot is attached to the
front burner. If needed, keep press-
ing ignitor button until pilot lights.

Note:

If pilot does not stay lit, con-

tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure
.

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

Note:

If pilot goes out, repeat steps

3 through 7. This heater has a safety
interlock system. Wait one (1) minute
for system to reset before lighting
pilot again.

OPERATING
HEATER

Continued

8.

Turn control knob counterclockwise

C-clockwise

to desired heating level. The

burners should light. Set control
knob to any heat level between HI
and LO.

CAUTION: Do not try to adjust

heating levels by using the
manual shutoff valve.

Figure 25 - Pilot
(

Note: Appearance of pilot assembly may

vary by model.)

Thermocouple

Ignitor
Electrode

Pilot Burner

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise

Clockwise

to

the OFF position.

Shutting Off Burners Only (pilot
stays lit)

Turn control knob clockwise

Clockwise

to

the PILOT position.

THERMOSTAT CONTROL

OPERATION

(Thermostat-Controlled Models

Only)

The thermostat control knob can be set to
any comfort level between Hi and Lo. The
thermostat will gradually modulate the
heat output and flame height from higher
to lower settings, or pilot, in order to
maintain the comfort level you select.
The ideal comfort setting will vary by
household depending upon the amount of
space to be heated, the output of the
central heating system, etc.

Note:

Selecting the Hi setting with the

control knob will cause the burner to
remain fully on, without modulating down
in most cases.

MANUAL LIGHTING

PROCEDURE

1.

Follow steps 1 through 5 under Light-
ing Instructions
, page 16.

2.

Depress control knob and light pilot
with match.

3.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8 above.