Owner’s manual, Optional positioning of thermostat sensing bulb – Vanguard Managed Solutions PRVYS18PWA User Manual

Page 21

Advertising
background image

21

104343

OWNER’S MANUAL

OPTIONAL
POSITIONING OF
THERMOSTAT
SENSING BULB

FOR MASONRY AND
FACTORY-BUILT METAL
FIREPLACE

If your log set cycles to pilot, but the
room temperature drops to a lower
than ideal comfort level before the log
set comes back on, you may want to
reposition the thermostat sensing bulb.

The thermostat sensing bulb is located near
the gas valve assembly on the mounting
bracket. This location allows the thermostat
to keep the room temperature at an ideal
comfort level for most fireplace applica-
tions. For positioning the thermostat sens-
ing bulb elsewhere, an adhesive-backed
mounting clip has been provided.

Tools needed: 1/4" hex driver or socket

1.

Remove logs. Locate the gas valve as-
sembly and thermostat sensing bulb
(see Figure 28).

2.

The adhesive-backed mounting clip
(see Figure 29) is attached to the ther-
mostat sensing bulb. Remove the ad-
hesive-backed mounting clip.

3.

With 1/4" hex driver or socket, loosen
the thermostat screw. Carefully slide
the thermostat sensing bulb out of the
retaining clamp (see Figure 30).

Note:

Do not remove the screw. Make

sure you tighten the screw after remov-
ing the thermostat sensing bulb.

IMPORTANT:

Do not force or bend the

thermostat sensing bulb or capillary.

4.

The thermostat sensing bulb may be
located to the lower right front side of
fireplace. Determine location of sens-
ing bulb, but do not mount sensing bulb
until step 5. If you have a masonry fire-
place, see Figure 31 for location. If you
have a factory-built metal fireplace, see
Figure 32 for location. If your fireplace
has glass doors, position sensing bulb
directly behind door gap on right bot-
tom side (see Figure 33).

Thermostat
Sensing Bulb

Figure 28 - Location of Gas Valve
Assembly and Thermostat Sensing Bulb

Figure 29 - Adhesive-backed Mounting
Clip

Figure 30 - Removing Thermostat Sensing
Bulb

Thermostat
Screw

Retaining
Clamp

Thermostat
Sensing Bulb

Capillary

Gas Valve Assembly

Mounting
Bracket

Adhesive-
backed
Mounting
Clip

Figure 31 - Locating Thermostat Sensing
Bulb on Masonry Fireplace

Thermostat
Sensing
Bulb

,

,

,

,

Q

Q

Q

Q

Adhesive-
backed
Mounting
Clip

Thermostat
Sensing Bulb

Figure 32 - Locating Thermostat Sensing
Bulb on Factory-built Metal Fireplace

,

,

,

,

Q

Q

Q

Q

,

Q

,

,

,

,

Q

Q

Q

Q

Adhesive-
backed
Mounting Clip

Glass Doors

Figure 33 - Installing Thermostat Sensing
Bulb behind Glass Doors

Thermostat
Sensing
Bulb

Thermostat
Sensing
Bulb

Capillary

Do Not Crimp
Capillary

Adhesive-
backed
Mounting
Clip

Figure 34 - Positioning the Thermostat
Sensing Bulb in the Vertical Position with
the Capillary at the Bottom

5.

The mounting clip must be a minimum
of 3" from bottom of fireplace to pre-
vent crimping of capillary. Once you
have decided on a location, clean the
area thoroughly. Remove the paper
backing from the adhesive on back of
mounting clip. Press the clip into the
new location so that the thermostat
sensing bulb will be positioned verti-
cally with the capillary at the bottom
(see Figure 34). Slide the thermostat
sensing bulb into the clip.

IMPORTANT:

Do not crimp capillary.

Advertising