104343

OWNER’S MANUAL

Figure 7 - Minimum Mantel Clearances When Using Hood

Minimum Non-
Combustible
Material

8"
Min.

12"

15"

18"

All minimum
distances are
in inches

Log Sets
All Models

20"

2

1

/2

"

6"

8"

10"

12"

Distances to
Underside of
Mantel

Hood
(GA6050, GA6052)

Top of Fireplace
Opening

Underside of
Mantel Shelf

Mantel Shelf

INSTALLATION

Continued

Figure 6 - Minimum Mantel Clearances Without Using Hood

Mantel Clearances

In addition to meeting non-combustible
material clearances, you must also meet
required clearances between fireplace open-
ing and mantel shelf. If you do not meet the
clearances listed below, you will need a
hood.

Determining Minimum Mantel
Clearance

If you meet minimum clearance between
mantel shelf and top of fireplace opening, a
hood is not required (see Figure 6).

Determining Minimum Mantel Clear-
ance When using a Hood

If minimum clearances in Figure 6 are not
met, you must have a hood. When using a
hood there are still certain minimum mantel
clearances required. Follow minimum clear-
ances shown in Figure 7 when using hood.

Minimum Non-
Combustible
Material

Minimum Non-
Combustible
Material Height

Distances to
Underside of
Mantel

Top of Fireplace
Opening

Underside of
Mantel Shelf

Mantel Shelf

12"

8"

(A)

18"

8"

20"

14"

22"

16

3/4

"

24"

20"

All minimum
distances are
in inches

Log Set
24"/30"/36" Models

18" Model

2

1

/2

"

6"

8"

10"

Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level

Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring

14"
Min.

Combust
Material

Non-Combustible M

Hearth

5"
Min.

Combustible
Material

Combustible
Material

Non-Combustible
Material

Hearth

Combustible
Material

5”
Min.

Floor Clearances

A. If installing appliance on the floor level,

you must maintain the minimum dis-
tance of 14" to combustibles (see Fig-
ure 8).

B. If combustible materials are less than

14” to the fireplace, you must install
appliance at least 5” above the com-
bustible flooring (see Figure 9).

NOTICE: If your installation does
not meet the minimum clearances
shown, you must do one of the
following:
• operate the logs only with the

flue damper open

• raise the mantel to an accept-

able height

• remove the mantel

Continued