104343

UNVENTED PROPANE/LP GAS LOG HEATER

VANGUARD FLAME-MAX

®

INSTALLATION

Continued

Minimum Non-combustible
Material Clearances

If Not Using Mantel

You must have non-combustible material(s)
above the fireplace opening. Non-combus-
tible materials (such as slate, marble, tile,
etc.) must be at least 1/2 inch thick. With
sheet metal, you must have non-combus-
tible material behind it. Non-combustible
material must extend at least 8" up (for all
models). If non-combustible material is less
than 12", you must install the fireplace hood
accessory (24", 30", and 36” models only).
See Figure 4 on page 7 and Figure 5 for
minimum clearances.

IMPORTANT:

If you cannot meet these

minimum clearances, you must operate
heater with chimney flue damper open. Go
to Installing Damper Clamp Accessory for
Vented Operation,
page 10.

If Using Mantel

You must have non-combustible material(s)
above the fireplace opening. Non-combus-
tible materials (such as slate, marble, tile,
etc.) must be at least 1/2 inch thick. With
sheet metal, you must have non-combus-
tible material behind it. Non-combustible
material must extend at least 8 inches up (for
all models). If non-combustible material is
less than 12", you must install the fireplace
hood accessory (24", 30”, and 36" models
only). Even if non-combustible material is
more than 12", you may need the hood
accessory to deflect heat away from your
mantel shelf. See Figure 5 and Figures 6 and
7, page 9, for minimum clearances.

IMPORTANT:

If you cannot meet these

minimum clearances, you must operate
heater with chimney flue damper open. Go
to Installing Damper Clamp Accessory for
Vented Operation,
page 10.

Non-Combustible

Requirements for

Material Distance (A)

Safe Installation

12" or more

Non-combustible material OK.

Between 8" and 12"

24", 30", or 36” Models: Install fireplace hood accessory

(GA6050, GA6052, or GA6053 see Accessories, page 30).

18" Model: Non-combustible material OK.

Less than 8"

Non-combustible material must be extended to at least 8".
See Between 8" and 12", above. If you cannot extend
material, you must operate heater with flue damper
open.

Figure 5 - Heat Resistant Material (Slate,
Marble, Tile, etc.) Above Fireplace

Heat Resistant
Material

(A)

Advertising