22

VM4016 Programming

INHOUSE:PSEUDO

The INHOUSE:PSEUDO command controls the use of the register interface. Pseudo set true
specifies that pseudo register interface should be used. Pseudo set false specifies that the hardware
register interface should be used. The value set takes effect next time the unit powers up [does not
take effect immediately]. The pseudo register interface allows the use of REG_ENABLE and
CLEAR_LATCH capability from the registers. Although the hardware register interface is much
faster than the pseudo register interface, it lacks the above two features. It is important to note that
when the module is shipped from the factory, pseudo is set to 1. It is also important to note that all
letters of the command must be provided as there is no short form for this command.

INHOUSE:PSEUDO <boolean>

Where <boolean> is 0 | OFF | 1 | ON.

EXAMPLES


INHOUSE:PSEUDO 1

Sets the pseudo register interface ON. (The
unit must be powered for the change to take
effect.)


INHOUSE:PSEUDO?

Returns 1 which states that the register

1

interface is set to pseudo.