86 - User's Manual

Drive the digital output

Note: This request requires the privilege of viewer.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/dido/setdo.cgi?do1=<state>[&do2=<state>][&do3=<state>][&do4=<state>]
[&return=<return page>]

Where state is 0, 1. “0” means inactive or normal state while “1” means active or triggered state.

Parameter

Value

Description

do<num>

0,
1

0 => inactive, normal state

1 => active, triggered state

return

<return page>

Redirect to the page <return page> after the parameter
is assigned. The <return page> can be a full URL path or
relative path according the current path. If you omit this
parameter, it will redirect to an empty page.

Example: Drive the digital output 1 to triggered state and redirect to an empty page

http://myserver/cgi-bin/dido/setdo.cgi?do1=1

Query status of the digital input

Note: This request requires the privilege of viewer.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/dido/getdi.cgi?[di0][&di1][&di2][&di3]

If no parameter is specified, all the status of digital input will be returned.

Return:

HTTP/1.0 200 OK\r\n
Content-Type: text/plain\r\n
Content-Length: <length>\r\n
\r\n
[di0=<state>]\r\n
[di1=<state>]\r\n
[di2=<state>]\r\n
[di3=<state>]\r\n

where <state> can be 0 or 1.

Example: Query the status of digital input 1