INSTALLATION

Continued

CONNECTING TO GAS SUPPLY

WARNING: This appliance

requires a 45° male flare fitting

5/8"-18 UNF (Unified National Fine

Thread) inlet connection and the

flexible gas line provided.

WARNING: A qualified

service person must connect

fireplace to gas supply. Follow

all local codes.

CAUTION: Never connect pro-

pane/LP fireplace directly to the

propane/LP supply. This fireplace

requires an external regulator

(not supplied). Install the external

regulator between the fireplace

and propane/LP supply.

WARNING: Never connect

natural gas fireplace to private

(non-utility) gas wells. This

gas is commonly known as

wellhead gas.

For propane/LP units, installer must supply an

external regulator. The external regulator will

reduce incoming gas pressure. You must reduce

incoming gas pressure to between 11 and 14

inches of water. If you do not reduce incoming gas

pressure, fireplace regulator damage could occur.

Install external regulator with the vent pointing

down as shown in Figure 21. Pointing the vent

down protects it from freezing rain or sleet.

CAUTION: Use only new,

black iron or steel pipe. Inter-

nally-tinned copper tubing may

be used in certain areas. Check

your local codes. Use pipe of

1/2" or greater diameter to allow

proper gas volume to fireplace.

If pipe is too small, undue loss

of volume will occur.

Installation must include a equipment shutoff valve,

union, and plugged 1/8" NPT tap. Locate NPT tap

within reach for test gauge hook up. NPT tap must

be upstream from fireplace (see Figure 22).
IMPORTANT:

Install equipment shutoff valve

in an accessible location. The equipment shutoff

valve is for turning on or shutting off the gas to

the appliance.

Propane/LP
Supply Tank

External
Regulator

Figure 21- External Regulator with Vent

Pointing Down

Vent
Pointing
Down

Figure 22 - Gas Connection

CSA Design-Certified
Equipment Shutoff Valve
With 1/8" NPT Tap*

PROPANE/LP
From External
Regulator (11" W.C.
to 14" W.C. Pressure)
NATURAL
From Gas Meter
(5" W.C. to
10.5" W.C.
Pressure)

3" Minimum

Pipe Cap Tee
Nipple

Joint

Sediment Trap

* Purchase the optional CSA design-certified

equipment shutoff valve from your dealer. See

Accessories, page 30.

Extension Cord
Use extension cord if needed. The cord must have

a three-prong, grounding plug and a three-hole

receptacle. Make sure cord is in good shape. It must

be heavy enough to carry the current needed. An

undersized cord will cause a drop in line voltage. This

will result in loss of power and overheating. Use a No.

16 AWG cord for lengths less than 50 feet.