Cleaning and maintenance – Vanguard Heating VMH26TPC User Manual

Page 22

Advertising
background image

www.desatech.com

113111-01D

22

CLEANING AND

MAINTENANCE

WARNING: Turn off fireplace

and let cool before cleaning.

CAUTION: You must keep

control areas, burner, and cir-

culating air passageways of

fireplace clean. Inspect these

areas of fireplace before each

use. Have fireplace inspected

yearly by a qualified service

person. Fireplace may need

more frequent cleaning due to

excessive lint from carpeting,

bedding material, pet hair, etc.

WARNING: Failure to keep

the primary air opening(s) of

the burner(s) clean may result in

sooting and property damage.

BURNER INJECTOR HOLDER AND
PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount

of air to mix with the gas. This provides a clean

burning flame. Keep these holes clear of dust, dirt,

lint, and pet hair. Clean these air inlet holes prior to

each heating season. Blocked air holes will create

soot. We recommend that you clean the unit every

three months during operation and have heater

inspected yearly by a qualified service person.
We also recommend that you keep the burner

tube and pilot assembly clean and free of dust and

dirt. To clean these parts we recommend using

compressed air no greater than 30 PSI. Your local

computer store, hardware store, or home center

may carry compressed air in a can. You can use a

vacuum cleaner in the blow position. If using com-

pressed air in a can, please follow the directions on

the can. If you donʼt follow directions on the can,

you could damage the pilot assembly.
1. Shut off the unit, including the pilot. Allow

the unit to cool for at least thirty minutes.

2. Inspect burner, pilot, and primary air inlet

holes on injector holder for dust and dirt (see

Figure 35).

3. Blow air through the ports/slots and holes in

the burner.

4. Check the injector holder located at the end

of the burner tube again. Remove any large

particles of dust, dirt, lint, or pet hair with a

soft cloth or vacuum cleaner nozzle.

5. Blow air into the primary air holes on the

injector holder.

6. In case any large clumps of dust have now been

pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the

pilot flame indicates dust and dirt in the pilot as-

sembly. There is a small pilot air inlet hole about

two inches from where the pilot flame comes out

of the pilot assembly (see Figure 36). With the unit

off, lightly blow air through the air inlet hole. You

may blow through a drinking straw if compressed

air is not available.

CABINET

Air Passageways
• Use a vacuum cleaner or pressurized air to

clean.

Exterior
• Use a soft cloth dampened with a mild soap and

water mixture. Wipe the cabinet to remove dust.

Figure 36 - Pilot Inlet Air Hole

(Propane/LP Shown)

Pilot Assembly

Pilot Air Inlet Hole

Figure 35 - Injector Holder On Outlet

Burner Tube

Burner Tube

Injector
Holder

Primary Air Inlet Holes

Ports/Slots

Advertising
This manual is related to the following products: