www.desatech.com

113111-01D

6

ASSEMBLY

Continued

5. Reattach screen by placing the notches in the

screen frame over the shoulder screws and

pushing down.

Assembling Hood
1. Locate four black phillips sheet metal screws

from the hardware packet.

2. Rotate hood as shown in Figure 3. Make sure

hood tabs point toward fireplace.

3. Insert hood tabs between baffle and louvers

(see Figure 3).

4. Gently rotate hood to upright position. Make

sure hood tabs are behind louvers and hood

is resting on firebox top (see Figure 3).

5. Align screw holes on hood with screw holes

on firebox top.

6. Insert screws as shown in Figure 3. Tighten

screws firmly.

Figure 3 - Assembling Hood

Hood

Louver

Hood Tab

Baffle

Sheet Metal
Screw

Firebox Top

Hood Tabs

AIR FOR COMBUSTION

AND VENTILATION

WARNING: This heater shall

not be installed in a confined

space or unusually tight construc-

tion unless provisions are provid-

ed for adequate combustion and

ventilation air. Read the following

instructions to insure proper fresh

air for this and other fuel-burning

appliances in your home.

Todayʼs homes are built more energy efficient

than ever. New materials, increased insulation, and

new construction methods help reduce heat loss

in homes. Home owners weather strip and caulk

around windows and doors to keep the cold air out

and the warm air in. During heating months, home

owners want their homes as airtight as possible.
While it is good to make your home energy effi-

cient, your home needs to breathe. Fresh air must

enter your home. All fuel-burning appliances need

fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel

burning appliances draw air from the house to

operate. You must provide adequate fresh air for

these appliances. This will insure proper venting

of vented fuel-burning appliances.

PROVIDING ADEQUATE
VENTILATION

The following are excerpts from National Fuel

Gas Code, ANSI Z223.1/ NFPA 54, Section 5.3,

Air for Combustion and Ventilation.
All spaces in homes fall into one of the three fol-

lowing ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 6 through 8 will help

you classify your space and provide adequate

ventilation.
Unusually Tight Construction
The air that leaks around doors and windows

may provide enough fresh air for combustion and

ventilation. However, in buildings of unusually

tight construction, you must provide additional

fresh air.