Troubleshooting – Vanguard Heating VMH26TPC User Manual

Page 25

Advertising
background image

www.desatech.com

113111-01D

25

TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Residues from manufacturing

processes

1. Turning control knob to HI

position when burner is cold

2. Air in gas line

3. Air passageways on fireplace

blocked

4. Dirty or partially clogged

burner orifice

1. When heated, vapors from

furniture polish, wax, carpet

cleaners, etc. may turn into

white powder residue

1. Metal expanding while heating

or contracting while cooling

REMEDY

1. Problem will stop after a few

hours of operation

1. Turn control knob to LO

position and let warm up for

a minute

2. Operate burner until air is re-

moved from line. Have gas line

checked by local propane/LP

gas company

3. Observe minimum installa-

tion clearances (see pages 9

through 12)

4. Clean burner (see Cleaning

and Maintenance, page 22)

or replace burner orifice

1. Turn heater off when using

furniture polish, wax, carpet

cleaners, or similar products

1. This is common with most

fireplaces. If noise is exces-

sive, contact qualified service

person

OBSERVED PROBLEM

Slight smoke or odor during

initial operation

Fireplace produces a whistling

noise when burner is lit

White powder residue forming

within burner box or on adjacent

walls or furniture

Fireplace produces a clicking/

ticking noise just after burner

is lit or shut off