Troubleshooting – Vanguard Heating VMH26TPC User Manual

Page 24

Advertising
background image

www.desatech.com

113111-01D

24

POSSIBLE CAUSE

1. Control knob not fully pressed

in

2. Control knob not pressed in

long enough

3. Safety interlock system has

been triggered

4. Equipment shutoff valve not

fully open

5. Thermocouple connection

loose at control valve

6. Pilot flame not touching ther-

mocouple, which allows ther-

mocouple to cool, causing

pilot flame to go out. This

problem could be caused by

one or both of the following:

A) Low gas pressure

B) Dirty or partially clogged

ODS/pilot

7. Thermocouple damaged

8. Control valve damaged

1. Burner orifice is clogged

2. Inlet gas pressure is too low

1. Manifold pressure is too low

2. Burner orifice is clogged

1. Burner orifice is clogged or

damaged

2. Burner damaged

3. Low inlet gas pressure

4. Gas regulator defective

1. Not enough air

2. Gas regulator defective

REMEDY

1. Press in control knob fully

2. After ODS/pilot lights, keep

control knob pressed in 30

seconds

3. Wait one minute for safety in-

terlock system to reset. Repeat

ignition operation

4. Fully open equipment shutoff

valve

5. Hand tighten until snug, then

tighten 1/4 turn more

6. A) Contact local propane/LP

or natural gas company

B) Clean ODS/pilot (see

Cleaning and Maintenance,

page 22) or replace ODS/pilot

assembly

7. Replace pilot assembly

8. Replace control valve

1. Clean burner (see Cleaning

and Maintenance, page 22)

or replace burner orifice

2. Contact local propane/LP or

natural gas company

1. Contact local propane/LP or

natural gas company

2. Clean burner (see Cleaning

and Maintenance, page 22)

or replace burner orifice

1. Clean burner (see Cleaning

and Maintenance, page 22)

or replace burner orifice

2. Replace burner pressure

3. Contact local propane/LP or

natural gas company

4. Replace gas regulator

1. Check burner for dirt and

debris. If found, clean burner

(see Cleaning and Mainte-

nance, page 22)

2. Replace gas regulator

OBSERVED PROBLEM

ODS/pilot lights but flame

goes out when control knob is

released

Burner does not light after

ODS/pilot is lit

Delayed ignition of burner

Burner backfiring during com-

bustion

Yellow flame during burner

combustion

TROUBLESHOOTING