6. With control knob pressed in, push down

and release ignitor button. This will light

pilot. The pilot is attached to the front of

burner. If needed, keep pressing ignitor

button until pilot lights.

Note:

If pilot does not stay lit, refer to

Troubleshooting, page 23. Also contact a

qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match. To light pilot with match, see

Manual Lighting Procedure.

7. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

Note:

If pilot goes out, repeat steps 3

through 7. This fireplace has a safety in-

terlock system. Wait one (1) minute before

lighting pilot again.

8. Turn control knob counterclockwise

to desired heating level. The main burner

should light. Set control knob to any heat

level between HI and LO.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

OPERATING FIREPLACE

Continued

Ignitor Button

Figure 28 - Control Knob In The OFF

Position

Control Knob

Thermocouple

Pilot Burner

Figure 29 - Pilot (Propane/LP Shown)

Ignitor Electrode

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

1. Turn control knob clockwise

to the

OFF position.

2. Turn off all electric power to the appliance

if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise

to the

PILOT position.

THERMOSTAT

CONTROL OPERATION

The thermostatic control used on this fireplace

differs from standard thermostats. Standard ther-

mostats simply turn on and off the burner. The

thermostat used on this fireplace senses the room

temperature. The thermostat adjusts the amount of

gas flow to the burner. This increases or decreases

the burner flame height. At times the room may

exceed the set temperature. If so, the burner will

shut off. The burner will cycle back on when room

temperature drops below the set temperature.

The control knob can be set to any heat level

between HI and LO.
Note:

The thermostat sensing bulb measures

the temperature of air near the fireplace cabinet.

This may not always agree with room tempera-

ture (depending on housing construction, instal-

lation location, room size, open air temperatures,

etc.). Frequent use of your fireplace will let you

determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 5 under Lighting

Instructions,

starting on page 19, column 1.

2. With control knob pressed in, strike match.

Hold match to pilot until pilot lights.

3. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob. Now follow step 8 under

Lighting Instructions

, column 1.