Operating heater – Vanguard Heating VN18A User Manual

Page 14

Advertising
background image

www.desatech.com

113052-01A

14

OPERATING HEATER

NON-THERMOSTAT MODELS

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not fol-

low these instructions exactly,
a fire or explosion may result
causing property damage, per-
sonal injury or loss of life.

A. This appliance has a pilot which must be

lighted by hand. When lighting the pilot,
follow these instructions exactly.

B. BEFORE LIGHTING smell all around the

appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electric switch; do not

use any phone in your building.

• Immediately call your gas supplier from

a neighbor’s phone. Follow the gas
supplier’s instructions.

• If you cannot reach your gas supplier, call

the fire department.

C. Use only your hand to push in or turn the

gas control knob. Never use tools. If the
knob will not push in or turn by hand, don’t
try to repair it, call a qualified service tech-
nician or gas supplier. Force or attempted
repair may result in a fire or explosion.

D. Do not use this appliance if any part has

been under water. Immediately call a quali-
fied service technician to inspect the appli-
ance and to replace any part of the control
system and any gas control which has been
under water.

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information above.

2.

Make sure equipment shutoff valve is fully
open.

3.

Turn control knob clockwise

to the

OFF position.

4.

Wait five minutes to clear out any gas. Then
smell for gas, including near the floor. If
you smell gas, STOP! Follow “B” in the
safety information above. If you don’t smell
gas, go to the next step.

5.

Turn control knob to PILOT/IGN and press in.

Note:

You may be running this heater for

the first time after hooking up to gas sup-
ply. If so, you may need to press in control
knob for 30 seconds or more. This will al-
low air to bleed from the gas system.

• If control knob does not pop up when re-

leased, contact a qualified service person
or gas supplier for repairs.

6.

With control knob pressed in, push down
and release ignitor button. This will light
pilot. The pilot is attached to the front of
burner. If needed, keep pressing ignitor but-
ton until pilot lights.

If pilot does not light

• turn control knob clockwise

to the

OFF position

• repeat steps 5 and 6
If pilot does not stay lit after several tries

• refer to Troubleshooting, pages 20

through 22

• contact a qualified service person or gas

supplier for repairs

Until repairs are made, light pilot with
match. To light pilot with match, see
Manual Lighting Procedure
, page 15.

7.

Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.

Note:

If pilot goes out,

repeat steps 3 through 7.

OFF

Ignitor Button

Control Knob

Figure 19 - Control Knob In The OFF

Position for Non-Thermostat Models

Figure 20 - Pilot

Ignitor Electrode

Pilot
Burner

Thermocouple

Advertising
This manual is related to the following products: