Inspecting heater, Pilot flame pattern, Burner flame pattern – Vanguard Heating VN18A User Manual

Page 18

Advertising
background image

www.desatech.com

113052-01A

18

GRH/OV 008

BAD PILOT/LP

GRH/OV 007

GOOD PILOT/LP

Thermocouple

Pilot Burner

Pilot Burner

Thermocouple

Blue Flame

Yellow Flame

Figure 27 - Correct Pilot Flame Pattern

Figure 28 - Incorrect Pilot Flame Pattern

Figure 29 - Correct Burner Flame Pattern

INSPECTING HEATER

Check pilot flame pattern and burner flame pat-
tern often.

PILOT FLAME PATTERN

Figure 27 shows a correct pilot flame pattern. Figure
28 shows an incorrect pilot flame pattern. The incor-
rect pilot flame is not touching the thermocouple.
This will cause the thermocouple to cool. When the
thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Fig-
ure 28

• turn heater off (see To Turn Off Gas to Appli-

ance, page 15 or 17, depending on your model)

• see Troubleshooting, pages 20 through 22

Note:

The pilot flame on natural gas units will

have a slight curve, but flame should be blue and
have no yellow or orange color.

Figure 30 - Incorrect Burner Flame

Pattern

BURNER FLAME PATTERN

Figure 29 shows a correct burner flame pattern.
Figure 30 shows an incorrect burner flame pattern.

If burner flame pattern is incorrect, as shown in
Figure 30

• turn heater off (see To Turn Off Gas to Appli-

ance, page 15 or 17, depending on your model)

• see Troubleshooting, pages 20 through 22

Bad Burner Pattern-Plaque

GRH/OV 019