Operating heater, Continued, Lighting instructions – Vanguard Heating VN18A User Manual

Page 16: Turn thermostat control knob counter- clockwise

Advertising
background image

www.desatech.com

113052-01A

16

OF

F

PI

LO

T

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information, page
15, column 2.

2.

Make sure equipment shutoff valve is fully
open.

3.

Turn thermostat control knob clockwise

Clockwise

to the OFF position (see Figure 22

or 23 for your model).

4.

Wait five minutes to clear out any gas. Then
smell for gas, including near the floor. If
you smell gas, STOP! Follow “B” in the
safety information, page 15, column 2. If
you don’t smell gas, go to the next step.

5.

Turn thermostat control knob counter-
clockwise

C-clockwise

to the PILOT position.

Press in thermostat control knob for 5 sec-
onds (see Figure 22 or 23 for your model).

Note:

You may be running this heater for

the first time after hooking up to gas supply.
If so, you may need to press in thermostat
control knob for 30 seconds or more. This
will allow air to bleed from the gas system.

• If thermostat control knob does not pop

up when released, contact a qualified ser-
vice person or gas supplier for repairs.

6.

Keep thermostat control knob pressed in while
pushing down and releasing the ignitor but-
ton. This will light pilot. If necessary, continue
to press ignitor button until pilot lights.

If pilot does not light
• turn thermostat control knob clockwise

Clockwise

to the OFF position

• repeat steps 5 and 6
If pilot does not stay lit after several tries
• refer to Troubleshooting
, pages 20 through 22
• contact a qualified service person or gas

supplier
Until repairs are made, light pilot with
match. To light pilot with match, see
Manual Lighting Procedure
, page 17.

7.

Keep thermostat control knob pressed in
for 30 seconds after lighting pilot. After 30
seconds, release control knob.

Note:

If pilot goes out, repeat steps 3

through 7. This heater has a safety inter-
lock system. Wait one minute before light-
ing pilot again.

OPERATING HEATER

Continued

8.

Turn thermostat control knob counter-
clockwise

C-clockwise

to the desired heating

level. For models, VP16TA, VN18TA,
VP26TA, and VN30TA, the main burner
should light. Set control knob to any heat
level between 1 and 5 (see Figure 25). For
infrastat models, the plaque directly above
the pilot should light.

CAUTION: Do not try to ad-

just heating levels by using the
equipment shutoff valve.

Figure 22 - Control Knob In The OFF

Position, Models VP16TA, VN18TA,

VP26TA, & VN30TA

Control Knob

Ignitor Button

Figure 24 - Pilot

Figure 25 - Burner Patterns

O

F

F

P

IL

O

T

O

F

F

P

IL

O

T

Control

Knob

VP16TA
VN18TA

VP26TA
VN30TA

Ignitor Electrode

Pilot Burner

Thermocouple

Figure 23 - Thermostat Control Knob In The

OFF Position, Models VP16ITA & VN22ITA

1

2

3

4

OF

F

PI

LO

T

Thermostat
Control Knob

Plaque Control
Knob

Ignitor
Button

Advertising
This manual is related to the following products: