S Y M P T O M

Spa Inoperative

MESSAGE

FLO

HILI

ICE

LS

SS

CP

REL

HC

P1/P2/P3

F1/F2/F3/F4

BUS

PAGE 20

DIAGNOSTIC & TROUBLESHOOTING

Resetting Your Spa

Like your PC at home, your spa electronics could get corrupted by electrical surges and operate improperly. If your spa
system is not operating properly or shows any of the following messages, please reset it before calling for service to
see if the malfunction disappears. To reset the spa, shut off the breaker for 5 sec. and turn it back on.

M E A N I N G

Power failure outside of spa.

Insufficient water flow through Heater.

HILI message appears if the high-limit
sensor detects 47.5°C (118°F) at both
the heater and spa water sensors.
DO NOT ENTER THE WATER.

Water in plumbing below 10°C (50°F)
Call for service if spa fails to come on.

Water temperature sensor

High Limit sensor

Circulation pump may be faulty

Relay Error

Heater Error

Pump 1, 2 or 3 fault

Blown Fuse

Communication Problem

A C T I O N

Check power source Breaker and GFCI; Reset
breaker/GFCI. Call Electrician if it will not start.

Clean/change filter element, (see page 4 for filter
part numbers.

Check pump for flow, on therapy side, check low
speed running. On swim side, check circ pump
running. If ”FLO” remains check need to prime
the pump(s).

Remove the spa cover and let the water temperature
cool down to 40°C (104°F). If your spa reaches
47.5°C (118°F) again, contact your dealer for service.
No action required.

Pump will come on to circulate water and then
heater. Heater will stay on until water reaches
15.5°C (60°F) or set temperature.

Reset spa. If message comes back, call for service.

Reset spa. If message comes back, call for service.

Check that circulation pump is plugged in, or for
possible loose connection. If message comes
back, call for service. This fault will lead to a FLO
message.

Relay not closing or opening correctly. Reset. If
message comes back, call for service.

Call for service. Heater may have to be replaced.

Check* plug for pump shown. Possible loose
connection.

Replace* bad fuse

Reset spa. If message comes back, call for service.

* These procedures should only be performed by persons familiar with electrical work.
ALWAYS SHUT THE POWER OFF AT THE DISCONNECT BEFORE ATTEMPTING THESE PROCEDURES.

Advertising