9. Electrical wires will need to be approximately 36 inches long.
Attach lines according to schematic shown.

Power Source

L8

L2

L1

T8

T2

T1

Fan

Thermostat

L1 - White (neutral)

L2 - Black (hot)

L3 - Black Silver Stripe

L8 - Green (ground)

T1 - White

T2 - Black

T3 - Black / White

T8 - Green

F1 - White

F2 - Black

F8 - Green

S1 - White

S2 - Black

J1 - White Jumper

Legend

Solenoid Valve

F8

F1

F2

T3

S1

S2

J1

J1

J1

WATER

LEAKING

WRONG

CORRECT

10. Install drain line fitting and drain line.
Excess moisture in the air will be condensed on the coil fins and captured in the base of the

evaporator unit. Therefore a drain line will need to be installed to drain the condensate. The

drain fitting is located in the center bottom of the unit. Attach the supplied drain line and

route it to a drain. A condensate pump may be required if a drain is not

readily available.

Install the drain line fitting to the bottom of the drain pan. The indoor

drain line must slope downward 1/4” to the foot and have no traps. The

line cannot run higher than the bottom of the drain pan and should not

have any kinks or blockage. When installing drain line inside of wall,

use copper or PVC to protect the drain tube from the elements.

-17-